ERP-Scale extension module: MT-SICS

You are here:

Commands

The following commands are supported:

Note: Custom device extensions are supported by ERP-Scale V5.0 which is currently in beta testing. Please contact us if you require further information.

Get scale’s current weight

Module level: L0

Request structure /SCWM/S_HU_SCALE

Field nameUseExample
G_WEIGHT  
UNIT_GW  
TEXT  
SCALE_ID  
WEIGHT_CNT  
SCALE_NAME*Name of device in ERP-ScaleICS689-M01

Note: Fields marked with * are required

Response structure /SCWM/S_HU_SCALE

Field nameValueExample
G_WEIGHTCurrent weight0.200
UNIT_GWUnit of measurekg
TEXT  
SCALE_ID  
WEIGHT_CNT  
SCALE_NAMEName of device in ERP-ScaleICS689-M01

Zero scale when stable

Module level: L1 -Basic

Request structure /SCWM/S_HU_SCALE

Field nameUseExample
G_WEIGHT  
UNIT_GW  
TEXT*ZEROZERO
SCALE_ID  
WEIGHT_CNT  
SCALE_NAME*Name of device in ERP-ScaleICS689-M01

Note: Fields marked with * are required

Response structure /SCWM/S_HU_SCALE

Field nameValueExample
G_WEIGHTCurrent weight0.200
UNIT_GWUnit of measurekg
TEXT  
SCALE_ID  
WEIGHT_CNT  
SCALE_NAMEName of device in ERP-ScaleICS689-M01

Set tare to scale’s current weight

Module level: L1 -Basic

Request structure /SCWM/S_HU_SCALE

Field nameUseExample
G_WEIGHT 200
UNIT_GW g
TEXT*TARETARE
SCALE_ID  
WEIGHT_CNT  
SCALE_NAME*Name of device in ERP-ScaleICS689-M01

Note: Fields marked with * are required.

Response structure /SCWM/S_HU_SCALE

Field nameValueExample
G_WEIGHTTare weight0.200
UNIT_GWUnit of measurekg
TEXT  
SCALE_ID  
WEIGHT_CNT  
SCALE_NAMEName of device in ERP-ScaleICS689-M01

Set tare to given weight

Module level: L2 -Advanced

Response structure /SCWM/S_HU_SCALE

Field nameValueExample
G_WEIGHTTare weight0.200
UNIT_GWUnit of measurekg
TEXT  
SCALE_ID  
WEIGHT_CNT  
SCALE_NAMEName of device in ERP-ScaleICS689-M01

Clear tare.

Module level: L1 -Basic

Request structure /SCWM/S_HU_SCALE

Field nameUseExample
G_WEIGHT  
UNIT_GW  
TEXT*CLEAR-TARECLEAR-TARE
SCALE_ID  
WEIGHT_CNT  
SCALE_NAME*Name of device in ERP-ScaleICS689-M01

Note: Fields marked with * are required.

Response structure /SCWM/S_HU_SCALE

Field nameValueExample
G_WEIGHT  
UNIT_GW  
TEXT  
SCALE_ID  
WEIGHT_CNT  
SCALE_NAMEName of device in ERP-ScaleICS689-M01

Set piece weight

Module level: L2 -Advanced

Request structure /SCWM/S_HU_SCALE

Field nameUseExample
G_WEIGHT*Weight of one piece23
UNIT_GW*Unit for weight of one pieceg
TEXT*SET-PIECEWEIGHTSET-PIECEWEIGHT
SCALE_ID  
WEIGHT_CNT  
SCALE_NAME*Name of device in ERP-ScaleICS689-M01

Note: Fields marked with * are required.

Response structure /SCWM/S_HU_SCALE

Field nameValueExample
G_WEIGHT  
UNIT_GW  
TEXT  
SCALE_ID  
WEIGHT_CNT  
SCALE_NAMEName of device in ERP-ScaleICS689-M01

Set target for piece weighing

Module level: L2 -Advanced

Note: Must be preceded by Set Piece Weight

Request structure /SCWM/S_HU_SCALE

Field nameUseExample
G_WEIGHT*Target quantity in pieces2230
UNIT_GW  
TEXT*SET-PIECE-TARGETSET-PIECE-TARGET
SCALE_ID*Lower limit in pieces2230
WEIGHT_CNT*Upper limit in pieces2400
SCALE_NAME*Name of device in ERP-ScaleICS689-M01

Note: Fields marked with * are required.

Response structure /SCWM/S_HU_SCALE

Field nameValueExample
G_WEIGHT  
UNIT_GW  
TEXT  
SCALE_ID  
WEIGHT_CNT  
SCALE_NAMEName of device in ERP-ScaleICS689-M01

Clear piece weight and target

Module level: L2 -Advanced

Request structure /SCWM/S_HU_SCALE

Field nameUseExample
G_WEIGHT  
UNIT_GW  
TEXT*CLEAR-TARGETCLEAR-TARGET
SCALE_ID  
WEIGHT_CNT  
SCALE_NAME*Name of device in ERP-ScaleICS689-M01

Note: Fields marked with * are required.

Response structure /SCWM/S_HU_SCALE

Field nameValueExample
G_WEIGHT  
UNIT_GW  
TEXT  
SCALE_ID  
WEIGHT_CNT  
SCALE_NAMEName of device in ERP-ScaleICS689-M01