Upgrading ERP-Scale V5

You are here:

Upgrading from ERP-Scale V5.0.12850 to V5.0.13330

ERP-Scale V5 is a major new release of ERP-Scale. It is currently still under development. To support our customers we have made prelease installations available.

This guide covers upgrading to ERP-Scale V5.0.13330 from V5.0.12850. It has not been tested with earlier builds of ERP-Scale V5.

An utility to upgrade from ERP-Scale V4.0.1 and ERP-Scale V4.0.2 will be provided later.

ERP-Scale V5.0.1 can be download here: ERP-Scale V5.0 Downloads.

Installing ERP-scale V5.0.13330

Create a backup of your existing configuration by exporting the registry settings:

Computer\HKEY_LOCAL_MACHINE\SOFTWARE\PocketPrograms

ERP-Scale can be installed over an existing installation of ERP-Scale V5.0.12850. There is no need to uninstall ERP-Scale V5.0.12850 first.

Restart the PC once the installation is finished.

After installation, open the ERP-Scale configuration utility.

Upgrading device drivers

The devices must be upgraded to the generic drivers for V5.0.13330.

When the configuration is opened for the first time, you will be prompted to upgrade the device drivers:

Select Yes, and await for confirmation:

 

Thin clients and RDP

ERP-Scale V5.0.13330 can connect to devices redirected through an RDP session without using the ERP-Scale APP.

Open the device’s communication settings and set the process to run as a separate process in the user’s session:

Activate log to file for devices running in a separate process.

Parsing screen and data fields

Data field logging

Data fields are flagged for logging using a checkbox. If any data fields are assigned to the parameter LOG, remove the parameter assignment and tick the Log checkbox instead:

Parse string creation

A new pop-up window is used for mapping the string from the device to the data fields.

To access the pop-up, double click on the parse string field of a data field.

Check the conversion type.

Motion handling and parsing expressions

Motion handling is used to check if the data from the device is valid and trigger a re-read if not.
  • In ERP-Scale V5.0.13330 motion handling uses a data field.
  • Parsing strings can use expressions

To add motion handling to a device, create a new data field e.g Motion.

Enter an expression which returns a value of true when the data is invalid:

The Mettler MT-SICS protocol has a ‘S’ in the third position if the scale is still (i.e. no motion).

In the parsing screen, select the data field which indicates motion: