Mettler Toledo IND MT-SICS

The Mettler Toledo IND range of scales supports the MT-SICS protocol. We advise using DIALOG mode with the scale as it offers a robust communication method. The guide is based on the factory default communication settings for an IND570 scale. Check the current settings for your scale using the indicators menu. This documentation assumes that: […]

3

What are the settings for Transcell PC-150

ERP-Scale supports the Transcell PC-150 Bench Scale using the settings below. The settings are based on the factory settings for the Transcell PC-150  (see below and the attached user manual). ERP-Scale Communication settings ERP-Scale parsing settings Factory default settings for Transcell PC-150 Transcell PC-150 user manual

5

How to get the serial communication settings from WinWedge

Gathering the communication data from WinWedge® Open the WinWedge Setup utility: Open the Port dialog: Make a note of the communication settings. Then return to the WinWedge Setup utility. Open the Input Data Record Structure Dialog: Make a note of the End Of Record Event:

6

Using USB Scales with ERP-Scale

ERP-Scale is compatible with USB scales which support the HID POS interface protocol. To use a USB HID POS scale with ERP-Scale follow these steps: 1. Select interface type USB HID POS and select the USB device 2. Test the communications Click on the menu option Test. Click on “Simulate”. If the test is successful, […]

7

Integrating Modbus devices using ERP-Scale

ERP-Scale V4.0.2 adds functionality for converting responses from Modbus devices into human readable values that can then be interfaced to SAP. Ideal for reading values from industrial equipment into PI‑Sheets using ERP‑Scale with SAP ODA or to MII using ERP‑Scale’s XML connector. For further details regarding ERP-Scale V4.0.2 please contact us.

8

Determine serial port settings for your scale

Getting started First you must determine the communication parameters for your scale. You will need to know: Baud rate Data bits Stop bits Parity Flow control, typically none, hardware or Xon/Xoff Communication method: continuous or on-demand Any terminators A request string, if required The best place to start is the user manual for the scale. […]

13

Mettler Toledo Spider and Spider S scales

See the attached document which describes how to change the settings of the scale. Section numbers listed below refer to this document. This documentation assumes that: The computer is connected to the scale’s interface 1 The scale has been reset to factory standard settings (see section 3.3). The operating mode of the scale has been […]

14

Sartorius X3 scale using an RS-232 connection

The settings below are based on the X3 operating manual Edition 2 dated 01/02/2008. They have not been tested using a physical device and should be used as a basis for creating a device in ERP-Scale. Before configuring ERP-Scale, verify that the SMA protocol has been assigned to one of the RS232 ports on the […]

16

Mettler Toledo PS scales using serial connection

This FAQ describes how to configure ERP-Scale for use with a Mettler Toledo PS scale using serial communication. The settings are based on the default communication settings of the PS scale. See the attached document for information how to reset the scale to factory settings. ERP-Scale communication settings ERP-Scale parsing settings  

19

What are the settings for Mettler Toledo PS scale in USB mode?

The PS range of scales from Mettler Toledo (PS90, PS60, PS30, PS6L, PS3L) supports a USB connection. This connection is ideal for use with ERP-Scale as ERP-Scale supports the USB HID POS protocol and only a single cable is required for communication and to power the scale. Note: The PS range of scales also supports […]